Re: [MV] Electrical Problem

From: Muttguru@aol.com
Date: Tue Dec 25 2001 - 09:19:25 PST


In a message dated 24/12/01 18:47:30 GMT Standard Time, Alan.Zeichner@kp.org
writes:

<< The ground to the panel is intact. I'm going to start going through the TM
but I know there must be someone out there with knowledge that may save me
some time solving this. >>

Hello Alan.....
there are three possibilities here:-

1. Both circuit breakers are energised from the ignition switch. With the
igniition "ON", check each side of each circuit breaker to see if you have
voltage. It could be a broken circuit breaker......you should ascertain the
cause of this before trying to by-pass (even temporarily) the CB.

2. You may have a bad ground between the instruments and the instrument
panel, or maybe the panel itself is not earthing to the body.... try a wire
clipped to the instrument(s) and the other end to a KNOWN good earth.

3. Unlikely, but check that the live feed to the instruments from one of the
circuit breakers is wire no.27... you could have crossed the wires to the
other CB.

Let us know what you find.

Kind regards and Season's Greetings to all the Membership of this fine List !

Ken