Checked the thermostat (M35)

From: Bjorn Brandstedt (super_deuce@hotmail.com)
Date: Mon Oct 25 2004 - 09:18:10 PDT


Cooked the thermostat on the stove along with a thermocouple type
thermometer probe.

Begins to open: 185
Fully open :195-200
Close again when cooling off: 172-175

It's working, so the information in my previous post(s) holds true with a
good t-stat.

Thanks for your interest!

Regards,
Bjorn