Re: [MV] Remote Generator Start

From: Ryan Gill (rmgill@mindspring.com)
Date: Tue Jun 28 2005 - 15:24:03 PDT


At 11:09 PM +0100 6/28/05, Adrian Rees \(M1LCR\) wrote:
>Hi all
>I have a Russian GAZ 66 / R142 Radio Vehicle (well two of them) and have
>fired up the Generators on them, as I have just figured out the Remote Start
>/ Stop controllers.
>
>Question is this:
>They have each got 4 x 6V 80AH Lead Acid batteries in them,(in a series /
>parellal arrangement giving two 12V banks) which are now showing about 2V,
>in charge. As such the Generator won't charge because the coils aren't
>energised. Someone told me to put a 12V Battery momentarily accross one of
>the existing banks to energise the coils, and get them charging.

Since they've lost their charge, I'd go ahead and pull the batteries. Series batteries can get messed up (burned out) by being out of sync with their mate in the series. Best thing to do is to charge them up individually, check their electrolyte levels and recheck the charge, then put them back into service.

-- 
--
----------------------------------------------------------------