Re: [MV] Fire Extinguisher for M1008

From: Ryan Gill (rmgill@mindspring.com)
Date: Sat Jan 01 2005 - 20:14:46 PST


At 7:41 PM -0500 1/1/05, David B wrote:
>Unfortunately Halon extinguishers have been
>banned under the CFC laws because they are ozone
>depleting chemicals. Halon can only be used in
>places where nothing else can be used such as
>some chemical production equipment with fixed
>closed systems and Crazy String. Go figure! If
>you find any Halon extinguishers for sale (NOS)
>they are legal to sell remaining stock, so grab
>them.

Which is why you can go with halogenated fire
extinguishers that work as well as halon and
better than CO2 but still are entirely gaseous.
Halotron and Energen are two agents.

Energen is a mix of Argon, CO2 and Nitrogen

Halotraon is an environmentally safe three
component chemical blend based on HCFC-123.

CO2 is good, but you need to have a lot of it to
deal with a class A fire. A 20 lb CO2
extinguisher has a 2A rating.

-- 
--